One Signal-Noise Separation based Wiener Filter for Magnetogastrogram

12 Nov 2023  ·  Hua Li ·

Magnetogastrogram (MGG) signal frequency is about 0.05 Hz, the low-frequency environmental noise interference is serious and can be several times stronger in magnitude than the signals of interest and may severely impede the extraction of relevant information. Wiener filter is one classic denoising solution for biomagnetic applications. Since the reference channels are usually placed not far enough from the biomagnetic sources under test, they will inevitably detect the signals and the Wiener filters may produce ill-conditioned solutions. Considering the solutions to improve the signal-to-noise ratio (SNR) of Wiener filter output, there are few methods to separate the signals from the noises of the reference signal at the filter input. In this paper, a new signal processing framework called signal-noise separation based Wiener filter (SNSWF) is proposed that it separates the main noise as the input signal of the filter to improve the output SNR of Wiener filter. The filter was successfully applied to the noise suppression for MGG signal detection. Using the SNSWF, the filter SNR is 16.7 dB better than the classic Wiener filter.

PDF Abstract
No code implementations yet. Submit your code now

Datasets


  Add Datasets introduced or used in this paper

Results from the Paper


  Submit results from this paper to get state-of-the-art GitHub badges and help the community compare results to other papers.

Methods


No methods listed for this paper. Add relevant methods here