Cardiac Motion Analysis by Temporal Flow Graphs

24 Apr 2016  ·  V. S. R. Veeravasarapu, Jayanthi Sivaswamy, Vishanji Karani ·

Cardiac motion analysis from B-mode ultrasound sequence is a key task in assessing the health of the heart. The paper proposes a new methodology for cardiac motion analysis based on the temporal behaviour of points of interest on the myocardium. We define a new signal called the Temporal Flow Graph (TFG) which depicts the movement of a point of interest over time. It is a graphical representation derived from a flow field and describes the temporal evolution of a point. We prove that TFG for an object undergoing periodic motion is also periodic. This principle can be utilized to derive both global and local information from a given sequence. We demonstrate this for detecting motion irregularities at the sequence, as well as regional levels on real and synthetic data. A coarse localisation of anatomical landmarks such as centres of left/right cavities and valve points is also demonstrated using TFGs.

PDF Abstract
No code implementations yet. Submit your code now

Tasks


Datasets


  Add Datasets introduced or used in this paper

Results from the Paper


  Submit results from this paper to get state-of-the-art GitHub badges and help the community compare results to other papers.

Methods


No methods listed for this paper. Add relevant methods here